Section 3: Installing the Instrument
05/11 22 51209 Revision 2
3.2.8 Analog Output
Connection method: 4-pin plug-in terminal block
Number of outputs: 1 current output, output
voltage via external resistor
Output: Gross, net weight or via
Profibus
Range: 0/4 ... 20mA, configurable
Resolution: E.g. 0 - 20 mA in max.
40,000 counts
Linearity error: @ 0 - 20mA: <0,05 %
@ 4 - 20 mA: <0,025 %
Temperature effect: < 100 ppm/K
Load: 0 ... max. 500 ohms
Protected against short
circuit:
Yes
Electrical isolation: Yes
Cable length (shielded): 150 m (current output)
0/4 ... 20mA
Analog signal,
current output.
The current is supplied
directly via the terminals.
0 ... 10V
Analog signal,
voltage output
The voltage level
corresponds to the voltage
drop across the 500-ohm-
(10 ppm/K) resistor.